Replacement Part Locator
Stuck locating your part number? Click the button below for a guide
The MDR3 (USA) Pressure switch from Condor USA.
Diaphragm Media Resistance MDR3 (USA)
Acetylene, Butane, Diesel, Natural gas, Petrolium, Ethylene glycol, Glycerol, Fuel oil, Urine, Carbon dioxide, Carbonic acid, Air, Mineral oils, Vegetable oil, Propane, Silicon oil, Nitrogen, Synthetic oils, Water, Distilled water, Hydrogen, Sea water, Hydrogen, Water steam
| Rated insulation voltage (Ui) | = 690 V |
| Motor switching capacity (UL 508, CSA 22.2) [Ue=120 V (1~)] | = 2 HP |
| Motor switching capacity (AC3) [Ue=240 V (1~)] | = 5,5 kW |
| Motor switching capacity (UL 508, CSA 22.2) [Ue=240 V (1~)] | = 3 HP |
| Motor switching capacity (AC 3) [Ue=240 V (3~)] | = 5,5 kW |
| Motor switching capacity (UL 508, CSA 22.2) [Ue=240 V (3~)] | = 7,5 HP |
| Motor switching capacity (AC 3) [Ue=400 V (3~)] | = 7,5/11* kW |
| Motor switching capacity (UL 508, CSA 22.2) [Ue=480 V (3~)] | = 15 HP |
| Motor switching capacity (AC 3) [Ue=500 V (3~)] | = 7,5/11* kW |
| Motor switching capacity (UL 508, CSA 22.2) [Ue=600 V (3~)] | = 20 HP |
| Motor switching capacity (AC 3) [Ue=690 V (3~)] | = 7,5/15* kW |
Stuck locating your part number? Click the button below for a guide
23028970 (244226)
23028988
23028996
23029002
23029010
24032179
24032187
MDR3E3/6.3
MDR3E3/10
MDR3E3H/16
MDR3F3/10